慶應義塾大学学術情報リポジトリ(KOARA)KeiO Associated Repository of Academic resources

慶應義塾大学学術情報リポジトリ(KOARA)

Home  »»  Listing item  »»  Detail

Detail

Item Type Article
ID
KO50001004-00010001-0019  
Preview
Image
thumbnail  
Caption  
Full text
KO50001004-00010001-0019.pdf
Type :application/pdf Download
Size :673.8 KB
Last updated :Oct 9, 2014
Downloads : 548

Total downloads since Oct 9, 2014 : 548
 
Release Date
 
Title
Title 変圧器絶縁劣化及び故障の検出法  
Kana ヘンアツキ ゼツエン レッカ オヨビ コショウ ノ ケンシュツホウ  
Romanization Henatsuki zetsuen rekka oyobi kosho no kenshutsuho  
Other Title
Title Detection of insulation deteriorations and locations of transformer  
Kana  
Romanization  
Creator
Name 森, 元吉  
Kana モリ, モトキチ  
Romanization Mori, Motokichi  
Affiliation 慶應義塾大学教授  
Affiliation (Translated) Prof. of Keiogijuku University  
Role  
Link  
Edition
 
Place
東京  
Publisher
Name 慶應義塾大学工学部  
Kana ケイオウ ギジュク ダイガク コウガクブ  
Romanization Keio gijuku daigaku kogakubu  
Date
Issued (from:yyyy) 1948  
Issued (to:yyyy)  
Created (yyyy-mm-dd)  
Updated (yyyy-mm-dd)  
Captured (yyyy-mm-dd)  
Physical description
 
Source Title
Name 慶應義塾大学工学部研究報告  
Name (Translated) Proceedings of Faculty of Engineering, Keiogijuku University  
Volume 1  
Issue 1  
Year 1948  
Month 4  
Start page 19(19)  
End page 27(27)  
ISSN
 
ISBN
 
DOI
URI
JaLCDOI
NII Article ID
 
Ichushi ID
 
Other ID
 
Doctoral dissertation
Dissertation Number  
Date of granted  
Degree name  
Degree grantor  
Abstract
The insulations of transformer and generater will be deteriorated or injured and even if the deterioration proceeds to the layer short or grounding, it will be difficult to point out the insulation faults, unless the facts are recongnized from outer circumference, that the current flowing, local heating smelling, and carbonizing. Before the insulation faults extends to be recognized from the outer circumference, there is a period which the local conductivity of insulation is growing or something like pin holes are in causing. If the deterioration of insulation in earlier state is detected, exactly from the outer circumference, we will be able to study rapidly how to cope with the situation. Thus we can not only protect against the fault, but also the continuation of runing will be kept reliably. By this method, the defects of insulation may be detected by using the impulse voltage according to the impulse level of the transformer insulation.
 
Table of contents

 
Keyword
 
NDC
 
Note
目次のタイトル : 変圧機器絶縁劣化及び故障の検出法
CONTENTSのタイトル : Detection of insuiation deteriorations and faults of transformer
 
Language
日本語  
Type of resource
text  
Genre
Departmental Bulletin Paper  
Text version
publisher  
Related DOI
Access conditions

 
Last modified date
Oct 09, 2014 11:23:43  
Creation date
Oct 09, 2014 11:23:43  
Registerd by
mediacenter
 
History
 
Index
/ Public / Faculty of Science and Technology / Keio Science and Technology Reports / 1(1948) / 1(1) 194804
 
Related to
 

Ranking

most accessed items
1st Open-domain dial... (1560) 1st
2nd 石垣島の「エコツ... (642)
3rd Bidet toilet use... (490)
4th 731部隊と細菌戦 ... (473)
5th 新自由主義に抗す... (373)

most downloaded items
1st アセトアニリドの... (932) 1st
2nd Potent mouse mon... (478)
3rd インフルエンサー... (468)
4th Genotype-phenoty... (439)
5th 中和滴定と酸塩基... (409)

LINK

慶應義塾ホームページへ
慶應義塾大学メディアセンターデジタルコレクション
慶應義塾大学メディアセンター本部
慶應義塾研究者情報データベース