Item Type |
Article |
ID |
|
Preview |
Image |
|
Caption |
|
|
Full text |
KO50001004-00360001-0001.pdf
Type |
:application/pdf |
Download
|
Size |
:367.5 KB
|
Last updated |
:Feb 18, 2015 |
Downloads |
: 827 |
Total downloads since Feb 18, 2015 : 827
|
|
Release Date |
|
Title |
Title |
Pulse width of nitrogen laser depending on pressure, a repetition rate electrode separation
|
Kana |
|
Romanization |
|
|
Other Title |
|
Creator |
Name |
Shimura, Hiroshi
|
Kana |
シムラ, ヒロシ
|
Romanization |
|
Affiliation |
Department of Instrumentation Engineering, Faculty of Science and Technology, Keio University
|
Affiliation (Translated) |
|
Role |
|
Link |
|
Name |
大場, 勇治郎
|
Kana |
オオバ, ユウジロウ
|
Romanization |
Oba, Yujiro
|
Affiliation |
Department of Instrumentation Engineering, Faculty of Science and Technology, Keio University
|
Affiliation (Translated) |
|
Role |
|
Link |
|
|
Edition |
|
Place |
|
Publisher |
Name |
慶應義塾大学理工学部
|
Kana |
ケイオウ ギジュク ダイガク リコウガクブ
|
Romanization |
Keio gijuku daigaku rikogakubu
|
|
Date |
Issued (from:yyyy) |
1983
|
Issued (to:yyyy) |
|
Created (yyyy-mm-dd) |
|
Updated (yyyy-mm-dd) |
|
Captured (yyyy-mm-dd) |
|
|
Physical description |
|
Source Title |
Name |
Keio Science and Technology Reports
|
Name (Translated) |
|
Volume |
36
|
Issue |
1
|
Year |
1983
|
Month |
2
|
Start page |
1
|
End page |
9
|
|
ISSN |
|
ISBN |
|
DOI |
|
URI |
|
JaLCDOI |
|
NII Article ID |
|
Ichushi ID |
|
Other ID |
|
Doctoral dissertation |
Dissertation Number |
|
Date of granted |
|
Degree name |
|
Degree grantor |
|
|
Abstract |
In the typical Blumlein-type nitrogen laser, the dependence of laser pulse width on pressure, a repetition rate and electrode separation is discussed. As the pressure increases, the pulse width decreases owing to the increase of the discharge channel resistance. The repetition rate of the laser pulse is adjusted by using a thyratron as a trigger switch. The pulse width increases with the increasing repetition rate. When the repetition rate exceeds a certain threshold, the laser emission stops. This reason is discussed with respect to a destruction time of metastables of nitrogen molecules. The effects caused by changing electrode separation and adding the third electrode are also discussed. The third electrode makes the pulse width short by pre-ionization.
|
|
Table of contents |
|
Keyword |
|
NDC |
|
Note |
|
Language |
|
Type of resource |
|
Genre |
Departmental Bulletin Paper
|
|
Text version |
|
Related DOI |
|
Access conditions |
|
Last modified date |
|
Creation date |
|
Registerd by |
|
History |
|
Index |
|
Related to |
|